The DT cabinet centrifugal fan product page on indblower.com identifies the DT Series as a low-noise cabinet centrifugal fan for hotels, theatres, civil buildings and industrial plants. When preparing a selection request, use the product table together with the installation information the page asks buyers to confirm: the layout, operating medium and required airflow duty.
What the DT product page provides
The technical data is divided into sections labelled “DT Single speed series” and “DT Double speed series.” The tables list model designation, power in kilowatts, rotation in revolutions per minute, volume in cubic metres per hour, pressure in pascals and static pressure in pascals. Read each model row across all of its columns so that the model and values stay together.
Read one row as a complete set
For example, the displayed 9-inch entry in the DT Single speed table shows 0.55 kW power and 900 r/min rotation. In the same row, volume is shown as 1328~3171 m³/h, pressure as 218~209 Pa and static pressure as 198~154 Pa. These figures reproduce the values in the product table in their displayed order. They are product-page data, not a recommendation for a specific building or duct system.
Other model rows carry different values. Avoid comparing only the power rating or model size: check the airflow and both pressure columns against the project duty. If a particular table entry appears suitable, ask the supplier to confirm the correct operating point and configuration for the installation.
Prepare the project information
The DT product page advises confirming the installation layout, operating medium and required airflow duty against the relevant product catalogue before selection. A useful enquiry can therefore identify:
- The application and installation location.
- The proposed layout and connection arrangement required by the project.
- The operating medium.
- The required airflow duty and the system pressure information available to the project team.
- The DT table section and model row being considered.
Providing these details helps the supplier review the request against the published data. Where the project conditions are not represented in the product table, request confirmation instead of assuming a listed row is suitable.
How to compare catalogue entries
Keep units consistent when you compare rows, and distinguish the pressure column from static pressure. Also note whether the selected entry comes from the single-speed or double-speed table section. The product page does not replace a project-specific selection review, so confirm the intended duty and arrangement with the supplier before finalizing a choice.
For the complete specifications, see the DT Series Cabinet Centrifugal Fans product page. You can also browse the Cabinet & Box Fans catalogue or share project details through the indblower.com contact page.
For a quotation or selection review, identify the intended DT model row only as a starting reference and include the operating medium, installation layout and airflow duty requested on the product page. If the project team has system pressure information, include it with the enquiry so the relevant pressure columns can be reviewed. The product page provides a contact route for quotation requests; the supplier can confirm which catalogue entry matches the stated conditions.
FAQ
What applications does the DT product page list?
It lists hotels, theatres, civil buildings and industrial plants as typical applications.
Which data columns appear in the DT tables?
The page lists model, power, rotation, volume, pressure and static pressure.
What should be confirmed before selection?
The product page says to confirm the installation layout, operating medium and required airflow duty against the relevant product catalogue.
Do the published table values confirm suitability for every project?
No. The table provides product data. Ask the supplier to confirm the applicable model and operating point for the actual project conditions.